Positioner Does Not Come On
If the positioner does not come on, proceed as follows:
1. Verify that the 46 CM - 60 CM switch (on the back panel) is all the way to
the left or right. If switch is in the middle, positioner may not turn on. See Figure
25.
2. If switch is in the correct position, unplug positioner from AC power.
3. Inspect positioner AC power cord for cuts, abrasions, etc. If defective,
return to Winegard Service Dept. If power cord is OK, proceed to next step.
4. Disconnect all cables from rear of positioner. Plug positioner back into AC
power. If positioner comes on, there is a short in the cables that connect to the
positioner; proceed to next step. If positioner does not come on, contact your
dealer or Winegard Service Dept.
5. Reconnect one cable to positioner, then plug positioner back into AC
power. If positioner turns on, repeat step until positioner does not turn on. The
cable that shuts the positioner off is the one with the short.
6. If the cable with the short is the control cable, proceed to step 6. If one of
the other cables is faulty, repair/replace cable as required to correct problem.
7. Unplug positioner. Remove mount from mount base. Disconnect the
cable that is faulty at the mount.
8. Plug positioner back into AC power. If positioner does not turn on, then the
35' cable from positioner to the mount is faulty. Repair/replace as required to
correct problem. If positioner does turn on, the faulty cable is in the mount.
Contact your dealer or Winegard Service Dept. before proceeding.
WARNING
INDICATOR
IGN
46 CM 60CM
WINEGARD
P/N:2750225
120 VAC 60Hz
100 WATTS MAX
REMOTE
CONTROL
PANEL
Make sure switch is all the
way left or right depending
on whether your antenna is
46 cm (18") or 60 cm (24").
Figure 25