HELI 86
two pre-determined settings through the use of the flight mode
switch. As different flight modes are selected (Normal, 1, 2,
Hold), the Gyro’s sensitivity rate will switch to the pre-determined
compensation rate for each particular flight mode in use.
Gyro Installation/Adjustment
JR NEJ-120S Gyro
Gyro Sensitivity Adjustment
Manual Gyro Sensitivity Adjustment
1. Connect the white connector from the NEJ-120S gain
controller to the AUX 2 channel of the receiver.
2. Select the manual gyro sensitivity feature (RUDD D/R will
appear on the XP8103 screen).
3. Adjust the 0 position under the RATE on the display to 100%
and the 1 position to 0% using the + or - keys.
4. Adjust the gyro sensitivity for positions 0 and 1 on the
NEJ-120S gain controller.
5. Move the Rudder D/R switch from the low position to the
high position with the gyro ON to verify that it is functioning
properly, and note the “high/low” sensitivity values relative to
the dual rate switch. Refer to the NEJ-120S gyro instructions for
further information.
Automatic Gyro Sensitivity Adjustment
1. Connect the white connector from the NEJ-120S gain
controller to the AUX 2 channel of the receiver.
2. Select the Automatic Gyro Sensitivity Adjustment Feature
(“AUTO” will appear on the screen).
3. Adjust the 0 position under the RATE on the display to 100%
and the 1 position to 0% using the + or - keys.
4. Under Function Mode select the gyro rate (position #1 or
Position #0) that you wish to be active in each flight mode.
5. Turn the system ON and move the flight mode switch to its 3
positions with the gyro ON to verify that it is functioning
properly. Refer to the NEJ-120S gyro instructions for further
information.
4.12 Gyro Sensitivity Adjustment (Function Mode) cont.
Automatic or Manual
rate selection
(automatic shown)
Automatic Gyro Sensitivity Selection
Flight Mode Rate Selection:
NORM: Normal
STNT: Stunt
HOLD: Throttle Hold (when activated)
INVT: Inverted (when activated)
Press the UP and DN keys
simultaneously to enter/exit
the Function Mode
Press the DN and Select keys
simultaneously to access the
Function Mode List Display
Press to activate and
select Gyro Sensitivity
type (Manual or Auto)
INH
Manual
Auto
and to increase or
decrease Gyro
Sensitivity value for
NEJ 1000
Note: For NEJ120, set
the 0 position at 100%
and 1 postiion at 0%
Press to move
arrow to rate
position 0 or 1
and to select
rate values for
flight modes
Press to inhibit Gyro
Sensitivity when at the
Auto position, or to
set Gyro Sensitivity
values to 0% at the
arrow position
DN
SELECT
CH CH CLEARUP
To Program Mixing Function
To Revolution/
Acceleration Mixing
function
Press to move
cursor to position