AMX Mio Modero R-4 Universal Remote User Manual


 
Programming the Mio R-4
72
Mio Modero R-4
? Button Query Commands (Cont.)
?TEC
Get the current
text effect color
Syntax:
SEND_COMMAND <DEV>,"'?TEC-<vt addr range>,<button states range>'"
Variables:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons
(0 = All states, for General buttons 1 = Off state and 2 = On state).
custom event type = 1009:
Flag - Zero
Value1 - Button state number
Value2 - Actual length of string (should be 9)
Value3 - Zero
Text - Hex encoded color value (ex: #000000FF)
Text length - Color name length (should be 9)
Example:
SEND COMMAND Device,"'?TEC-529,1'"
Gets the button 'OFF state' text effect color information.
The result sent to the Master would be:
ButtonGet Id = 529 Type = 1009
Flag = 0
VALUE1 = 1
VALUE2 = 9
VALUE3 = 0
TEXT = #5088F2AE
TEXT LENGTH = 9
?TEF
Get the current
text effect name
Syntax:
SEND_COMMAND <DEV>,"'?TEF-<vt addr range>,<button states range>'"
Variables:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons
(0 = All states, for General buttons 1 = Off state and 2 = On state).
custom event type = 1008:
Flag - Zero
Value1 - Button state number
Value2 - Actual length of string
Value3 - Zero
Text - String that represents the text effect name
Text length - Text effect name length
Example:
SEND COMMAND Device,"'?TEF-529,1'"
Gets the button 'OFF state' text effect name information.
The result sent to the Master would be:
ButtonGet Id = 529 Type = 1008
Flag = 0
VALUE1 = 1
VALUE2 = 18
VALUE3 = 0
TEXT = Hard Drop Shadow 3
TEXT LENGTH = 18