AMX Mio Modero R-4 Universal Remote User Manual


 
Programming the Mio R-4
84
Mio Modero R-4
List Box Commands (Cont.)
^LVC
Set the table column display
order according to the order
of the entered column values
Set the table column display order according to the order of the entered column
values.
Syntax:
SEND_COMMAND <DEV>,"'^LVC-<view
address>,<column>,<column>…'"
Variables:
view address = the address of the view definition
column = the column number to display (first column is 1)
Example:
SEND_COMMAND Device,"'^LVC-3,5,2,1'"
Sets the column display order to column 5 first, then column 2 and then column
1. The data list is displayed according to the view definitions located at address
3.
^LVF
Filter a list by setting what
column to use and what
string to compare
Filter a list by setting what column to use and what string to compare. Note that
setting column to zero or data to none makes the filtered ordering the same as
sorted ordering. Update must be called for changes to take effect.
Syntax:
SEND_COMMAND <DEV>,"'^LVF-<view
address>,<uniflag>,<column>,<search data>'"
Variables:
view address = the address of the view definition
uniflag = indicates unicode; 0 - No unicode, 1 - Uses unicode
column = the starting column number (first column is 1)
search data = the data on which to filter
Example:
SEND_COMMAND Device,"'LVF-1,0,2,Smith'"
Filters list based on column 2 such that only those rows whose column 2
contains Smith are displayed. The data is displayed according to the view
definitions located at address 1. Filter is case sensitive.
^LVL
Set the data list to be
displayed
Set the data list to be displayed.
Syntax:
SEND_COMMAND <DEV>,"'^LVL-<view address>,<list
port>,<list address>'"
Variables:
view address = the address of the view definition
list port = 1-100. port where data resides
list address = address where data resides
Example:
SEND_COMMAND Device,"'^LVL-5,my songs'"
Sets the data list viewed to my songs and displays it according to the view def-
initions located at address 5.