AMX Mio Modero R-4 Universal Remote User Manual


 
Programming the Mio R-4
73
Mio Modero R-4
?TXT
Get the current
text information
Get the current text information.
Syntax:
SEND_COMMAND <DEV>,"'?TXT-<vt addr range>,<button states
range>,<optional index>'"
Variables:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons
(0 = All states, for General buttons 1 = Off state and 2 = On state).
optional index = This is used if a string was too long to get back in one command. The
reply will start at this index.
custom event type = 1001:
Flag - Zero
Value1 - Button state number
Value2 - Actual length of string
Value3 - Index
Text - Text from the button
Text length - Button text length
Example:
SEND COMMAND Device,"'?TXT-529,1'"
Gets the button 'OFF state' text information.
The result sent to the Master would be:
ButtonGet Id = 529 Type = 1001
Flag = 0
VALUE1 = 1
VALUE2 = 14
VALUE3 = 1
TEXT = This is a test
TEXT LENGTH = 14