Bosch Appliances 700 DVR User Manual


 
Divar 700 Series Hardware setup | en 29
Bosch Security Systems Installation and Operation manual F.01U.246.471 | v3.6 | 2011.11
4.6.2 CVBS
Connect the unit to CCTV monitors using 75 ohm video coaxial cables with BNC connectors.
The unit provides a 1 Vpp CVBS signal.
If the monitor has a loop-through connection without using the loop-through output, then
select the 75 ohm impedance setting on the monitor. If the monitor's loop-through output is
connected to an additional device, the device's termination is set to 75 ohm and the monitor's
termination is set to high impedance. (This is not necessary on devices with automatic
termination.)
Specifications
Output signal: Composite video 1Vpp, 75 ohm, Sync. 0.3Vpp ±10%
Resolution: 704 x 576 PAL, 704 X 480 NTSC
Connector type: BNC
Figure 4.9 CVBS monitor connectors (hybrid version)
4.6.3 Y/C
Connect the unit to a CCTV monitor with Y/C input, using a standard Y/C connection cable.
Figure 4.10 Y/C monitor connectors (hybrid version)
4.7 Monitor streaming connection (hybrid version)
To connect a monitor in a remote streaming configuration, connect the CVBS monitor output
to a video input. Then connect the monitor to the corresponding loop-through connector.
Figure 4.11 Typical monitor streaming connection (hybrid version)
CVBS
A
B
Y/C
A
B
KBD in
KBD out
IR ext
VGA CVBS Y/C Biphase
Com 1 Com 2
Alarm I/O
A
B
AA
BB
- | + | G
RS
485
MAL
OUT
N0 | C | NC
Video in
Video out
Video in
Video out
Video in
Video out
1234
1234
5678
5678
9101112 13141516
9101112 13141516
AC
USBUSB
Ethernet
Audio out Audio in
AB
L
R
13579111315
2 4 6 8 10 12 14 16
Monitor out
B
A