Bosch Appliances 700 DVR User Manual


 
68 en | Advanced configuration Divar 700 Series
F.01U.246.471 | v3.6 | 2011.11 Installation and Operation manual Bosch Security Systems
6.2 Video & Audio
Use this menu to configure the video and audio inputs.
On DHR 730 models tabs 1-8 are for the analog cameras. Higher tabs are for IP cameras.
On DHR 750 models tabs 1-16 are for the analog cameras. Higher tabs are for IP cameras.
On DNR 730 models tabs 1-16 are for IP cameras.
On DNR 750 models tabs 1-32 are for IP cameras.
On models with expanded memory, (revision B models) the bitrates tab follows the camera
number tabs.
6.2.1 Analog Channels
The tabs 1-8 or 1-16 across the top of the menu contain the settings for each of the analog
inputs on a digital hybrid recorder.
Figure 6.4 Configuration menu - Video & Audio - Analog camera
A General tab and a Control tab are available for each analog camera.
General tab
Enter a name for the selected input. The name can be up to 16 characters long.
–The Enable video input setting enables (default) or disables the video and corresponding
audio inputs.
Auto contrast - enabled to let the system automatically adjust the contrast for the video
input.
Contrast - can be set manually with the slider if Auto contrast is disabled.
Enable Audio input when an audio source is connected.
–The Level meter indicates the strength of the audio input signal.
Use the Gain slider to adjust the input sensitivity.