Bosch Appliances 700 DVR User Manual


 
Divar 700 Series Operating instructions | en 63
Bosch Security Systems Installation and Operation manual F.01U.246.471 | v3.6 | 2011.11
5.10.2 Contact inputs
If a contact input causes an alarm
Monitors A and B (hybrid version only) can display an array of pre-selected cameras.
Monitor A: The border around the displayed cameos is red. The alarm icon is displayed in
the corresponding cameo. An alarm status message is displayed.
The alarm beeper sounds. The alarm and the indicators flash.
Controllable cameras might be moved to pre-defined positions.
5.10.3 Motion events
If a motion detection signal causes an event
Monitors A and B (hybrid version only) can switch to display the motion events.
The motion icon is displayed in the corresponding cameo. An alarm status message is
displayed.
The motion indicator on the front panel flashes.
5.10.4 Text events
If a text event signal causes an event
Monitors A and B (hybrid version only) can switch to display the text events.
The text event icon (yellow) or text alarm icon (red) is displayed in the corresponding
cameo. An alarm status message is displayed.
5.10.5 Video loss alarm
If the loss of a video signal causes an alarm:
Monitor A or B (hybrid version only) can be configured to show the video loss signal.
One or both monitors can switch to a multiscreen view. The lost camera signal is
displayed as a black cameo with the video loss message. On monitor A, the border
around the camera with the video loss is red. An alarm status message is displayed.
The alarm beeper sounds.
The video loss and indicators flash.
Acknowledging a video loss alarm
Press the acknowledge key to acknowlede a video loss alarm.
The beeper is silent.
The video loss and indicators are no longer lit.
The alarm status message disappears.
The last-used view mode is restored.
If the camera with video loss is visible, the black cameo and the video loss message continue
to be displayed as long as there is no video present.
If an alarm is not acknowledged, the beeper switches off after the dwell time but the alarm
still needs to be acknowledged.
If auto-acknowledge is enabled the beeper, and the video loss and indicators,
switch off after the dwell time.