Extron electronic TLP 700MV Universal Remote User Manual


 
TLP 700MV Rear Panel Features and Connections
11
12
13
Figure 4. TLP 700MV Rear Panel Features
k Power Connector — Connect the two pole, 3.5 mm captive screw connector from
the provided power supply to the power supply socket on the rear panel. Ensure the
connections have the correct polarity as shown below:
12V
0.4A MAX
POWER
Power Receptacle
DC Power Cord
Captive Screw Connector
AC Power Cord
Ground
+12 VDC
External
Power Supply
(12 VDC, 1 A )
SECTION A–A
Ridges
Smooth
Power Supply
Output Cord
AA
12V
0.4A MAX
POWER
3/16"
(5 mm) Max.
Figure 5. Power Supply Connection
CAUTION: Always use a power supply supplied by or specified by Extron. Use of an
unauthorized power supply voids all regulatory compliance certification
and may cause damage to the supply and the end product. Extron power
supplies are certified to UL/CSA 60950-1 and are classified as LPS (Limited
Power Source). Use of a non-LPS or unlisted power supply will void all
regulatory compliance certification.
Unless otherwise stated, the AC/DC adapters are not suitable for use in
air handling spaces or in wall cavities. The power supply is to be located
within the same vicinity as the Extron A/V processing equipment in an
ordinary location, Pollution Degree 2, secured to the equipment rack
within the dedicated closet, podium or desk.
The installation must always be in accordance with the applicable
provisions of National Electrical Code ANSI/NFPA 70, article 75 and the
Canadian Electrical Code part 1, section 16. The power supply shall not be
permanently fixed to building structure or similar structure.
TLP 700MV and TLP 700TV • Panel Features 6