62
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
Operation examples (continued)
3) Set each item in the <MOTION DETECTION SET-
TINGS> screen for all cameras ( see pages 39,40).
1
<MOTION DETECTION SETTINGS>
>>
SELECTION CAMERA NO.
DETECTION MASK SETTING
SENSITIVITY HIGH••<<<LOW
MOTION THRESHOLD 5
TEST MODE
4) <TIMER PROGRAM SETTINGS> screen setting (
see pages 44-46).
• SELECTED PATTERN : “P3”.
• ALARM REC DURATION : “5M”.
<TIMER PROGRAM SETTINGS>
SELECTED PATTERN P3-SET
HOLIDAY SETTING
REC MODE A
REC MODE B
REC MODE C
REC MODE D
>>
ALARM REC DURATION 5M
5) <REC MODE C> screen setting ( see page 46).
• MOTION DET REC : “ALARM”
• PRE ALARM REC : Set desired pre-alaem recording time.
<REC MODE C>
ALARM SETTING
RECORD SETTING
PRE ALARM REC ( S ) S
>>
MOTION DET REC ALARM
6) <ALARM SETTING C> screen setting ( see page
46).
• All cameras ( “
1
” ~ “
9
” ).
• TRIGGER : MD/EXT.
• EMR : All cameras ( “
1
” ~ “
9
” ) is setting.
<ALARM SETTING C> ALARM CH
ALARM RECORD CAMERA TRIGGER
1 -------- MD/EXT
2 - ------- MD/EXT
3 -- ------ MD/EXT
4 --- ----- MD/EXT
5 ---- ---- MD/EXT
6 ----- --- MD/EXT
7 ------ -- MD/EXT
8 ------- - MD/EXT
>>
9 -------- MD/EXT
EMR
9
7
4
5
6
1
2
3
8
<ALARM SETTING C>
9
7
4
5
6
1
2
3
8
7) <RECORD SETTING C> screen setting ( see page
46).
• Camera selection during alarm recording : “ALARM CH”.
• All cameras ( “
1
” ~ “
9
” ).
• PPS, GRADE, A-PPS, A-GRADE : Set desired interval
and picture quality for each camera.
When “0S” is selected, the pre-alarm recording
is inoperable.
7) <TIMER PROGRAM> screen setting (
see pages
44,45 ).
• PROGRAM NO.1 : “SPL”, “08:00”, “15:00”, “A”, “OFF”.
• PROGRAM NO.2 : “SPL”, “15:00”, “20:00”, “B”, “OFF”.
• PROGRAM NO.3 : “SAT”, “08:00”, “17:00”, “B”, “OFF”.
• PROGRAM NO.4 : “SUN”, “08:00”, “17:00”, “B”, “OFF”.
• PROGRAM NO.5 : “HOL”, “08:00”, “17:00”, “B”, “OFF”.
• SPL : “MON - FRI”.
<TIMER PROGRAM> P2
DW START END MODE MD
1
SPL 08:00
15:00 A OFF
2 SPL 15:00
20:00 B OFF
3
SAT 08:00 17:00 B OFF
4
SUN 08:00 17:00 B OFF
5
HOL 08:00 17:00 B OFF
6 --- --:-- --:-- ---- -
7 --- --:-- --:-- ---- -
8 --- --:-- --:-- ---- -
>>
SPL MON-FRI
When completed with all settings above and after clear-
ing the menu screen, press the TIMER button. The unit
will switch to the timer mode.
■ Operation example 3
This example illustrates the procedure for using Pre-alarm
recording, Alarm recording, Emergency recording with nor-
mal recording in Timer record mode.
< Operation >
• REC MODE C (pre-alarm recording, alarm recording and
emergency recording with all cameras) is set to Monday ~
Friday from 08:00 to 15:00 and REC MODE D (pre-alarm
recording, alarm recording and emergency recording with
camera number “
1
”, “
2
”, “
3
”, “
7
”, “
8
” and “
9
”) is
set to 15:00 ~ 08:00 of the following day.
• On weekends, REC MODE D (pre-alarm recording, alarm
recording and emergency recording with camera number
“
1
”, “
2
”, “
3
”, “
7
”, “
8
” and “
9
” ) is set to 08:00 ~
08:00 of the following day.
Next day
08:00
Next day
08:00
REC MODE C
REC MODE D
REC MODE D
From Monday
to Friday
Saturday and
Sunday
08:00
08:00
15:00
< Setting >
1) Set 1) ~ 3) of “Operation example “ 1 ” previous.
2) <REAR TERMINAL SETTINGS> screen setting (
see
page 51).
• EMERGENCY REC DURATION : “20M”.
<REAR TERMINAL SETTINGS>
MODE OUT 1 OFF
MODE OUT 2 OFF
MODE OUT 3 OFF
MODE OUT 4 OFF
MODE OUT 5 OFF
KEY SOUND ON
BUZZER OFF
REMAIN HDD MAIN-10
%
CALL OUT SETTINGS
>>
EMERGENCY REC DURATION 20M