Panasonic WJ-HD220 DVD Recorder User Manual


 
17
Notes:
Input rating: Low-active, non-voltage normally open (N.O.) contact
Output rating for pin #4 Alarm Recovery Out
*1
: High-active with a 200 resistor pulled up to +5 V
Output rating for pin #7 Alarm Out 2
*2
: High-active with a 4.7 kresistor pulled up to +12 V
Output rating for pin #6 Alarm Out 1: Low-active, maximum load capacity of +12 V 100 mA
Output rating for other pins: Low-active, maximum load capacity of 24 V 100 mA , open-collector with a 4.7 k resistor
pulled up to +5 V inside
• Pin #24 Sequence In receives a close contact input to advance the sequence one step. This input does not start a
sequence but forwards the presently running sequence by one step.
Pin #25 Sequence Out supplies a negative pulse when the sequence running on the multiscreen monitor advances one
step.
Alarm Connection
There are eight alarm inputs, while two outputs are provided with different driving capacity.
External Recording Connection
The recording mode will change from the internal timer
mode to the external mode (EXT REC MODE) specified in
REC SETUP menu when the switch is turned on.
Time Adjusting Connection
The internal timer is calibrated with this input.
Sensor
Door Switch
Alarm Input Terminals
Signal Ground Terminals
#7 Alarm Out 2 *2
External
Alarm
Reset Switch
#2 Alarm In 1
#3 Alarm In 2
Relay *1
Alarm Indicator
*1: Use when the indicator exceeds over the drive capacity of the alarm out terminal.
*2: Connect to #6 Alarm Out 1 when using a low-active device.
Master Clock
Non-voltage N.O. contact
N.O.=Normally Open
#13 Time Adjust In
#22 External Recording Mode