Pelco Manual C681M-D (2/02) 81
OTHERS
Description of problem Please consult the following
The unit will not respond to PC control.
The DEVICE CHECK menu does
appear when power is turned on.
The unit is not detecting its peripheral
recording device(s).
Black screens are being displayed
during multi-screen display.
Button operation is not working.
Button operation of camera numbers is
not working.
The unit will not detect motion.
Is the RS-232C setting set correctly?
Are the unit and computer connected correctly?
Is there a defect in the connecting cable?
Is the proper connecting cable being used?
Is the REMOTE communication indicator light on (DX3016 models only)? Press the REMOTE communica-
tion button to turn off the light.
Is peripheral device’s SCSI ID setting set correctly?
Inspect the connecting cable.
Is the SCSI terminator switch on?
Have the peripheral devices been disconnected?
Are the recommended peripheral devices being used?
Operations settings have not been made, in the Camera Operation Setting parameter of the DEFINE
GROUP SETTING. Input from cameras displaying the “ - ” symbol will appear black on the monitor.
Is the playback device indicator light blinking? Wait until the light stays on, then start operation once more.
If the light does not stop blinking for a long period, use the RESET button located at the back of the unit.
Is the LOCK function or the PASSWORD LOCK function in
effect? If so, please cancel the function(s).
Is the Menu screen being displayed? (Camera number buttons cannot be used when the Menu screen is
displayed.)
Is the unit currently accessing a peripheral recording device?
Check the ACCESS indicator.
Is the MOTION DETECTION setting ON in the Initial Set Up menu?
Is the value of the MOTION THRESHOLD setting greater than the dot value entered in the SET DETEC-
TION MASK setting?
The motion detection function will not work when menus are open. (The M-DET indicator light is off when
the motion detection function is not operating.)