Phonetics Boat Remote Universal Remote User Manual


 
Chapter 3: Programming
51
The local display will prompt for the Maximum Run Time. Using the
number keys on the keypad, enter the number of minutes, press
ENTER. Repeat for seconds. The default is 30 minutes and the range
is 1 second to 999 minutes 59 seconds.
Use the number keys to enter minutes.
Press ENTER.
Repeat for seconds.
The local display will prompt for the Cycle Rate alarm parameters.
The cycle rate alarm will trip whenever the number of on/off cycles of
the bilge pump exceeds the programmed time period. The default is
20 cycles/1 hour. The programmable range is 0 - 120 cycles/1 - 24
hours. A setting of 0 cycles disables the cycle rate alarm.
Using the number keys on the keypad enter the number of cycles,
press
ENTER. Type in the number of hours, press ENTER.
Use the number keys to enter the number of cycles.
Press ENTER.
Repeat for hours.
The display will prompt you to enter the Bilge Pump Input phone
selection. Use the number keys to select the phone numbers to be
dialed when the Bilge Pump Input is in alarm. You can choose all of