Page 1-29CHAPTER 1 — GETTING STARTED
Note: Refer to the alternate host serial interface users guide for
information regarding the appropriate communication parameters.
10. Press f. The display should read:
SERIAL0: BAUD=
11. Press g. The display should read:
BAUD= setting
where setting is the default baud rate for the alternate host.
12. If the baud rate shown is not correct, use d and f to select the
proper rate. When the baud rate is set, press ENTER. The display
should scroll to the right to read:
SERIAL0: BAUD=
13. Press f. The display should read:
SERIAL0: PARITY=
14. Press g. The display should read:
PARITY= setting
where setting is the default parity setting for the alternate host.
15. If the parity setting shown is not correct, use d and f to select the
proper setting. When the parity setting is set, press ENTER. The
display should scroll to the right to read:
SERIAL0: PARITY=
16. Press f. The display should read:
SERIAL0: LENGTH=
17. Press g. The display should read:
LENGTH= setting
where setting is the default word length (number of data bits) setting
for the alternate host.
18. If the length shown is not correct, use d and f to select the proper
value. When the length is set, press ENTER. The display should
scroll to the right to read:
SERIAL0: LENGTH=