Agilent Technologies 5250 TV Converter Box User Manual


 
19. Press f. The display should read:
SERIAL0: STOPS=
20. Press g. The display should read:
STOPS= setting
where setting is the default number of stop bits for the alternate
host.
21. If the stop bit setting shown is not correct, use d and f to select
the proper stop bit setting. When the value is set, press ENTER. The
display should scroll to the right to read:
SERIAL0: STOPS=
22. Press f. The display should read:
SERIAL0: FLOW=
23. Press g. The display should read:
FLOW= setting
where setting is the default flow control setting for the alternate
host.
24. If the flow control setting shown is not correct, use d and f to
select the proper setting. When the value is set, press ENTER. The
display should scroll to the right to read:
SERIAL0: FLOW=
25. Press s. The display will scroll to the left and should read:
CONFIG:SERIAL0:
SERIAL I/O PORT 0 is now configured. Unless using the other serial port
for alternate host input, move to Saving the Configuration.
To configure SERIAL I/O PORT 1 as an alternate host input port, simply
repeat this procedure for that port.