Bosch Appliances XF DVR User Manual


 
Divar XF Introduction | en 15
Bosch Security Systems Installation manual F.01U.135.429 | 2.5 | 2009.08
2.3 Installation environment
2.3.1 Mounting
The Divar XF is supplied as a desktop unit. If desired, the unit can be rack mounted using the
rack mounting kit supplied with the unit.
2.3.2 Ventilation
Ensure that the location planned for the installation of the unit is well ventilated. Take note of
the locations of the cooling vents in the unit's enclosure and ensure that they are not
obstructed.
2.3.3 Temperature
Observe the unit's ambient temperature specifications when choosing an installation space.
Extremes of heat or cold beyond the specified operating temperature limits may cause the
unit to fail. Do not install the unit on top of hot equipment.
2.3.4 Power Supply
Ensure that the site's AC power supply is stable and within the rated voltage of the unit. If the
site's AC power is likely to have spikes or power dips, use power line conditioning or an
uninterrupted power supply (UPS).
2.4 Associated equipment
A typical system could contain the following components (not included with the unit):
A primary monitor for multiscreen monitoring (monitor A)
A second monitor for spot/alarm monitoring (monitor B)
Cameras with 1 Vpp composite video outputs
IP cameras (see datasheet for supported models)
Amplified microphone(s)
Audio amplifier with speaker(s)
Video coaxial cable with BNC connectors for connecting the video signals
Audio cable with RCA connectors for connecting audio signals.
AC power supply outlet for the unit that allows for secure isolation (the unit has no on/
off switch for security reasons)
A KBD keyboard
PC for Control Center and Configuration Tool applications
Pan/tilt/zoom control units