Placing a hard disk
Figure 4.4 Placing a hard disk
1. Locate the first empty hard disk bay. It is recommended that you install the disks in order
from one to four, as labeled. (Note that disks 3 and 4 are mounted in a double bay.)
2. Unscrew the two torx T10 screws securing the selected bay. Slide the bay from the unit
by pulling it forward.
3. To replace an installed hard disk, remove the four installation screws, two per side, from
the sides of the bay. Remove the hard disk.
Mount the new hard disk into the bay with four screws, two per side (refer to the hard
disk documentation).
4. Align and slide the bay back fully into its slot in the unit.
5. Secure the bay using the two torx T10 screws removed earlier (step 2).
6. Repeat steps 1-5 for any additional hard disks.
Remounting the front panel
1. When disk installation is complete, reconnect the flat cable to the front panel, if
necessary.
2. Align and slide the front panel to the left until it is in place.
3. Refasten the two captive cross head screws to the front panel.
4.4 Camera connections
Connect cameras to the Video in connectors on the back of the unit using 75 ohm video
coaxial cables with BNC connectors. Optionally, this signal can be looped through to other
equipment via the corresponding Video out connector. The camera input connectors are auto-