Bosch Appliances XF DVR User Manual


 
26 en | Hardware setup Divar XF
F.01U.135.429 | 2.5 | 2009.08 Installation manual Bosch Security Systems
terminating. There is no need to add a terminator to the output connector if no additional
equipment is connected.
If the camera signal is looped-through to additional equipment, make sure that the end of the
video line is terminated with 75 ohm termination.
The DivarXF automatically configures itself as a PAL or NTSC unit. The unit determines the
standard by detecting the signal format of the first connected camera (lowest camera input
number).
Specifications
Input signal: Composite video 1 Vpp, 75 ohm
Color standard: PAL/NTSC, auto-detect
Gain control: Automatic or manual gain control for each video input
Connector type: BNC looped-through, automatic termination
Figure 4.5 Eight video inputs with loop-through outputs
4.5 Audio connections
The DivarXF supports up to 16 audio inputs and 4 audio outputs. Connect using audio cable
with RCA compatible connectors.
Specifications
Input signal: Mono RCA, 1 Vpp, 10k ohm
Output signal: Dual mono RCA, 1 Vpp, 10k ohm
Figure 4.6 Audio input connectors
Figure 4.7 Audio output connectors
4.6 Monitor connections
Up to two monitors can be connected through the VGA, CVBS, or Y/C connections.
4.6.1 VGA
Connect the unit to one or two VGA monitors using standard VGA cable. It is advised to use
17” monitors or larger when using LCD(s).
Video in
Video out
1234
1234
5678
5678
Audio in
13579111315
2
4
6
8
10
12
14
16
Audio out
AB
L
R