Bosch Appliances XF DVR User Manual


 
66 en | Advanced configuration menu Divar XF
F.01U.135.429 | 2.5 | 2009.08 Installation manual Bosch Security Systems
If DHCP is disabled, fill in the IP address, the Subnet mask, the Default gateway, and the
DNS Server address. If required, change the default HTTP port (80) to a new value.
Restrict the network bandwidth by entering a Mbps value between 0.1 and 100 for the
Bandwidth limit.
–The MAC address is read only; it shows the MAC address of the DVR.
Cable connected shows the status of the physical network connection.
6.8.2 IP Range
Eight IP ranges can be entered to allow access.
Enter the same begin and end address to specify a single IP address. Enter different
begin and end addresses to specify an IP address range.
6.8.3 Monitor Streaming
The remote monitor streaming function allows monitor output A and/or B to be streamed
remotely via one or more of the analog video inputs. The main advantage of using this feature
is that multi-screen images can be viewed remotely using just one video stream, thus requiring
only a limited amount of network bandwidth and computer resources.
Each of the analog video inputs can be configured as:
Camera input (default).
Streaming output A (input is used to stream monitor output A).
Streaming output B (input is used to stream monitor output B).
Note:
Disable the recording of a channel used for monitor streaming in the Recording tab.
Figure 6.10 Network menu - Monitor streaming