Edirol R-44 VCR User Manual


 
58
Setting sound quality (Effects settings)
1: 3-Band EQ
2: Graphic EQ
3: Noise Gate
Effects
No.
Parameter
name
Range of values
Default
values
Explanation
1 MID-F
200Hz, 250Hz, 315Hz,
400Hz, 500Hz, 630Hz,
800Hz, 1kHz, 1.25Hz,
1.6kHz, 2kHz, 2.5kHz,
3.15kHz, 4kHz, 5kHz,
6.3kHz
1kHz
Specifies the center frequency of the
mid-range equalizer.
2 MID-Q 0.5, 1.0, 2.0, 4.0, 8.0 2.0
Sets the range of the region centered
on the Mid Freq for which the gain
will change. Higher values narrow
the region in which the change oc-
curs.
3 LOW -12dB–0dB–+12dB 0dB
Adjusts the gain of the low-range
equalizer.
4 MID -12dB–0dB–+12dB 0dB
Adjusts the gain of the mid-range
equalizer.
5 HIGH -12dB–0dB–+12dB 0dB
Adjusts the gain of the high-range
equalizer.
6 LEVEL 0 - 120 100 Adjusts the overall volume.
No.
Parameter
name
Range of values
Default
values
Explanation
1 125Hz -12dB–0dB–+12dB 0dB Adjusts the gain at 125 Hz.
2 250Hz -12dB–0dB–+12dB 0dB Adjusts the gain at 250 Hz.
3 500Hz -12dB–0dB–+12dB 0dB Adjusts the gain at 500 Hz.
4 1kHz -12dB–0dB–+12dB 0dB Adjusts the gain at 1 kHz.
5 2kHz -12dB–0dB–+12dB 0dB Adjusts the gain at 2 kHz.
6 4kHz -12dB–0dB–+12dB 0dB Adjusts the gain at 4 kHz.
7 Level 0–120 100 Adjusts the overall volume.
No.
Parameter
name
Range of values
Default
values
Explanation
1 LO-CUT
OFF, 40Hz, 55Hz, 63Hz,
80Hz, 100Hz, 125Hz, 160Hz,
200Hz, 250Hz, 315Hz,
400Hz, 500Hz, 630Hz,
800Hz, 1kHz
100Hz
Cuts unwanted low-frequency noise
such as wind.
2 THRESHOLD OFF,1–100 20
Specifies the volume threshold be-
low which the sound will be cut.
3 LEVEL 0–120 100 Adjusts the overall volume.
R-44_e_new.book 58 ページ 2008年1月7日 月曜日 午後5時8分