EverFocus EDR1600 DVR User Manual


 
Administrators Guide and Operating Instructions
21
??Go to Preset- The option will be available while the focus camera is
a PTZ camera. Check the box and enter the desired preset location.
The corresponding PTZ camera will automatically go to the preset
location while the alarm action is triggered. For more details of the
preset location settings, please refer to Chapter 7 PTZ Control
Functions.
??Pre-record Pre-record time to define how long (in seconds) before
the Alarm Action is triggered the Focus Camera shall be intensively
recorded (Note 2). Use the Up/Down arrow buttons to adjust the
value (0-10 seconds).
??Post-record - Post-record time to define how long after the Alarm
Action is triggered the Focus Camera shall be recorded at Alarm
Recording Rate. Please refer to Camera Setup for Alarm Recording
Rate of Camera. Use the Up/Down arrow buttons to adjust the
value (0 seconds-60minutes).
??Enable Check to enable the Alarm Output when the Alarm Action
is triggered.
??Alarm Out To define which Alarm Output will be triggered when
the Alarm Action is triggered. NC and NO signals are available,
please refer to Alarm Out Setup. Click on the Down arrow button
to select one of the Alarm Outputs (AO 1-8).
??Output Alarm Out output state when the Alarm Action is triggered.
For NC signal, its always open, for NO signal close. The Normal
State above shows whether the selected Alarm Out is NC signal or
NO signal.
??Buzzer On To activate the internal buzzer or not when the Alarm
Action is triggered.
??Log Log to event log list or not. Please refer to Log Display for
the details.
??Show Message To display the alarm message or not when the
Alarm Action is triggered.
??Any Key To Stop When the Alarm Action is triggered, the internal
buzzer and Alarm Out relay may be activated. If you want to stop
those actions by pressing any key or moving/clicking the mouse,
please check this item.