Administrator’s Guide and Operating Instructions
22
??Record Audio – To enable audio recording function while the alarm
action is triggered.
??Call Display – If it is checked, the Call Monitor will switch to the
Focus Camera when the Alarm Action is triggered. Otherwise, the
Call Monitor will switch among the cameras according to setting.
Please refer to 6.15 Set Call Monitor for the setup details.
??Send Mail - To activate the e-mail notification function or not when
the Alarm Action is triggered. The e-mail will be sent to the defined
receivers with an attached file, which contains the video graphic file
of the alarm triggered moment. For general user, the attached video
graphic file will be in QCIF GIF file format (176x120 for NTSC,
176x144 for PAL). Please refer to Chapter 6.15 for e-mail
notification setting. (Note 3)
??Network Alarm – Reserved for the Power Com (Optional) users.
Please refer to the Power Com user manual for the detail information.
Note 1: When the Alarm Input that triggered the Alarm Action returns to normal,
the internal buzzer and the corresponding Alarm Output will return to
normal immediately.
Note 2: The processing power for the system is 25/50 FPS for PAL and 30/60 FPS
for NTSC(1xFPS/2xFPS model). So, if the total configured recording
rate for all the cameras is 5 FPS, intensive recording means that the actual
FPS for the Pre-record time for the Focus Camera is 5/10 times (for PAL)
or 6/12 times (for NTSC) the configured normal recording rate for the
Focus Camera. The formula is:
Fp = Fn x 25(50) / Ft for PAL, Fp = Fn x 30(60) / Ft for NTSC
Fp: Pre-record FPS, Fn: normal FPS for Camera n,
Ft: Total configured FPS.
Note 3: If the alarm action happened during the post record time from the previous
triggered alarm, there will be no notification sending for the corresponding
action.