14
Measure Mode (Up to 200 readings stored)
To start, press
Press
Press (measure)
Plug in transducer; press
Select units of measure using ; press
Select Peak, Track, Impulse or ‘Click Dip’ using ; press
Use Peak for direct drive tools, Track for diagnostics, Impulse for pulse tools, and ‘Click Dip’ for
click wrenches.
Select measurement direction using (Right is clockwise. Left is anti-clockwise);
press
Select ‘Cycle end Time’ using ; press (normal is 0.5 sec.)
Select frequency response using ; press
Type in Max torque value; press
Type in Min torque value; press
On
MENU
2
select proper transducer using
then press
If using I/S or H/O type transducers
continue with instructions.
If using SER, KPD or KEY, you are now
ready to take measurements.
Enter
Enter
Enter
Enter
Enter
Enter
Enter
Enter
Enter
7529_eng.fm Page 14 Wednesday, November 12, 2003 8:57 AM