24
1 beep/Amber LED = Torque value or Angle/Pulse count is low (if used)
2 beeps/Green LED = Torque value or Angle/Pulse count is OK (if used)
3 beeps/Red LED = Torque value or Angle/Pulse count is high (if used)
The final reading of a subgroup will be indicated by an extended beep.
If you make a mistake when taking a reading it can be erased by pressing .
If you continue to press you can erase all readings within the current subgroup. It is not
possible to erase readings taken in a previous subgroup.
No readings will be stored if the torque value is below the threshold value previously set.
If the characteristic has been configured with Subgroup comment size set to a value other than
0, then pressing will allow a subgroup comment to be entered.
Alternatively, when the cursor is flashing, you may connect a Bar Code Reader to the Printer/PC
connector on the back of the ETA5 and scan the information from a barcode. Scan across the
label (from left or right), and watch the display. If the flashing cursor disappears, the reading has
been captured; wait a few seconds for the reading to be displayed. If not, re-scan until the data
is accepted. If a further reading needs to be taken, press to clear the data and allow a
further scan to be taken or data to be keyed in.
Note: If the bar code data exceeds the number of characters reserved for
the comment, the ETA5 will beep and show an error message. The
data will not be accepted.
When the information is displayed on the screen, press
Pressing gives analysis of last completed subgroup. (Press again to continue.)
Pressing gives analysis of current subgroup, up to current reading. (Press again to
continue.)
Reset
Reset
Z
Reset
Enter
# #
. .
7529_eng.fm Page 24 Wednesday, November 12, 2003 8:57 AM