Panasonic WV-CU360C Home Theater Server User Manual


 
34
Item
Alarm Operation
When the WV-CU360C receives an alarm signal from a sys-
tem unit, the alarm indicator on the controller blinks.
The alarm indicator changes from blinking to steady light
when the alarm is automatically reset.
The camera number [---] appears in the camera section of
the LED display.
Alarm Reset
1. Press the ALM RESET/ALM RECALL button.
The alarm indicator on the controller goes off.
Notes:
Alarm reset operations including auto reset are
applied to all system units, not to a selected one.
Alarm reset mode differs depending on the system
unit connected to the WV-CU360C.
Confirm that the SHIFT button is released.
Alarm Suspension
The alarm suspension mode is activated or deactivated.
Use this function when you do not want to be disturbed by
alarm input as for example during setup operations.
1. Press the ALM SUSPEND button. The ALM SUSPEND
indicator lights up.
Alarm input is ignored while the indicator is lit.
ALM RESET
ALM RECALL
ALM
SUSPEND
2. To cancel alarm suspension, press the ALM SUSPEND
button again.
Note: The alarm suspension is applied to all system
units, not to a selected one.
Alarm Recall
The alarm event log is recalled and displayed on the moni-
tor.
1. Select the desired system unit and monitor.
2. Press the ALM RESET/ALM RECALL button while the
SHIFT indicator is lit. The ALM RECALL indicator lights
up. The alarm log appears on the monitor.
3. To cancel the alarm recall function, press the ALM
RESET/ALM RECALL button while the SHIFT indicator
is lit.
ALM
SUSPEND
ALM RESET
ALM RECALL