Panasonic WV-CU360C Home Theater Server User Manual


 
59
Controller Number Setting
Set this switch always to 1 when using the System
Controller with the WJ-SX350.
Switch Setting Procedures
Set the MODE DIP switch and CONTROLLER NO. switch as
follows.
1. Remove the DC plug from the rear of the controller.
2. Set the MODE switches.
Bit 1 through 3 should match the version of the WJ-
SX350 installed in your system. Open the SETUP MENU
of the WJ-SX350 and check the version shown in the
upper right corner of the menu.
For version 6.00 or later, set the switches as shown
below.
Bit 1 should be set to OFF*.
Bit 2 should be set to ON.
Bit 3 should be set to ON.
S E T U P M E N U 6.xx/1.xx
P R O G R A M
O P E R A T O R
S Y S T E M
C A M D A T A L O A D
C A M E R A T I T L E
C A M – P O S I M A P
F U N C T I O N K E Y
MODE
12345678
OFF
ON
For version 1.xx, set the switches as shown below.
Bit 1 should be set to OFF*.
Bit 2 should be set to ON.
Bit 3 should be set to OFF*.
Bits 4 through 8 are not version related.
Bit 4 should be set to OFF*.
Bit 5 should be set to ON*.
Bit 6 should be set to OFF* (Operator) normally, or
ON (Administrator) when setting up the controller.
Bit 7 should be set to OFF*. Baud rate selection is
automatic.
Bit 8 should be set to OFF* normally.
3. Connect the DC plug to the controller.
MODE
12345678
OFF
ON
0
9
8
7
6
5
4
3
2
1
CONTROLLER No.