Controller Number Setting
Set this switch always to 1 when using the System
Controller in a System 850.
Switch Setting Procedures
Set the MODE DIP switch and CONTROLLER NO. switch as
follows.
1. Remove the DC plug from the rear of the controller.
2. Set the switches as follows.
Bit 1 should be set to OFF*.
Bit 2 should be set to ON.
Bit 3 should be set to OFF*.
Bit 4 should be set to OFF*.
Bit 5 should be set to ON* when connecting with a
System 850 in a home run (one to one) fashion.
Bit 6 should be set to OFF* (Operator) normally, or ON
(Administrator) when setting up the controller.
Bit 7 should be set to ON. The baud rate is selected in
the controller setup.
Bit 8 should be set to OFF* normally.
3. Connect the DC plug to the controller.