■ Setup Procedures
Set up the baud rate and parity check mode for the controller while observing the LED on the front panel.
● Administrator Authorization
1. Press the CAM/SET button while [SEtUP] is displayed.
The [- - - - -] prompt appears.
2. Enter a password using the numeric buttons, then press
the CAM/SET button.
The default setting is [12345].
3. If the password entered is valid, [SPEED] appears. If
password entry failed, the menu returns to [SEtUP].
● Baud Rate
When bit 7 of the MODE switch is in the ON position, you
need to select the communication speed manually to match
that of the WJ-SX350.
1. Display [SPEED], and press the CAM/SET button twice.
2. Select a parameter entering a bracket-enclosed num-
ber, e.g., (3), or moving the joystick.
The default setting is 9 600 bps.
(1) 2 400: 2 400 bps
(2) 4 800: 4 800 bps
(3) 9 600: 9 600 bps *
(4) 19 200: 19 200 bps
Note: Selecting a slower rate (e.g., 2 400 bps) will
delay the response time (e.g., the time until an acti-
vated alarm is reset).
3. Press the CAM/SET button to validate the selection.
4. Press the MON/ESC button to return to the [SPEED]
menu.
● Parity
The parity check mode is selected in this menu.
1. Display [PrtY] and press the CAM/SET button twice.
2. Select a parameter with the joystick.
The default setting is None.
n: None
E: Even parity
3. Press the CAM/SET button to confirm the selection.
4. Press the MON/ESC button to return to the [SPEED]
menu.
Note: The baud rate and parity check mode of the WJ-
SX350 and the controller must be the same, otherwise
data communications will not function.
Menu
Selection
Move Joystick
UP and down
to select
Setup Menus
Parameter Selection (default*)
LED Display
blinking
Setup
Administrator
Password
Prompt
Speed
Parity
Initial
Display
Authorization
Baud Rate
(bps)
Press
twice
Parity Check