■ Setup Procedures
Set up the baud rate and parity check mode for the controller while observing the LED on the front panel.
● Administrator Authorization
1. Press the CAM/SET button while [SEtUP] is displayed.
The [- - - - -] prompt appears.
2. Enter a password using the numeric buttons, then press
the CAM/SET button.
The default setting is [12345].
3. If the password entered is valid, [SPEED] appears. If
password entry failed, the menu returns to [SEtUP].
● Baud Rate
When bit 7 of the MODE switch is in the ON position, you
need to select the communication speed manually to match
that of the WJ-SX350.
1. Display [SPEED], and press the CAM/SET button twice.
2. Select a parameter entering a bracket-enclosed num-
ber, e.g., (3), or moving the joystick.
The default setting is 9 600 bps.
(1) 2 400: 2 400 bps
(2) 4 800: 4 800 bps
(3) 9 600: 9 600 bps *
(4) 19 200: 19 200 bps
Note: Selecting a slower rate (e.g., 2 400 bps) will
delay the response time (e.g., the time until an acti-
vated alarm is reset).
3. Press the CAM/SET button to validate the selection.
4. Press the MON/ESC button to return to the [SPEED]
menu.
● Parity
The parity check mode is selected in this menu.
1. Display [PrtY] and press the CAM/SET button twice.
2. Select a parameter with the joystick.
The default setting is None.
n: None
E: Even parity
3. Press the CAM/SET button to confirm the selection.
4. Press the MON/ESC button to return to the [SPEED]
menu.
Note: The baud rate and parity check mode of the WJ-
SX350 and the controller must be the same, otherwise
data communications will not function.
Menu
Selection
Move Joystick
UP and down
to select
Setup Menus
Parameter Selection (default*)
LED Display
blinking
Setup
Administrator
Password
Prompt
Speed
Parity
Initial
Display
Authorization
Baud Rate
(bps)
Press
twice
Parity Check
CAM
SET
CAM
SET
MON
ESC
LED prompts you to enter pass-
word
Enter a 5-digit password,
press (12345*)
(1) 2 400 (2) 4 800 (3) 9 600*
(4) 19 200
(1) None* (2) Even
Reading Function
OK
No
DOWN
LR
UP
LR
CAM
SET