Working with Configurations 43
SmartNode 10200 Series User Manual 3 • Initial Setup and Web Management
Verifying that an Application is Operating
When an application’s target state is set to run, there are a number of crucial verifications that you should con-
duct in order to know that an application is running properly. These verifications are as follows:
• Verify the application’s current path. It is important that once the application has been set to run, a path
is displayed.
• Verify the TDM interface. If you are running a TDM application on your Smart Media unit then you can
verify the TDM interface. Although, you most likely have not yet configured the TDM interface of the
Smart Media unit, certain status LEDS will indicate that your application is operational.
• Verify the IP Interfaces. Your Smart Media unit is furnished with two IP interfaces for access to a VoIP
network. Although you have not as of yet configured the interfaces, certain LED indications will be dis-
played. See Figure 32 below.
Figure 32. SN10200 Interfaces
Verifying the Application Path
One important indication of the normal operation of an application is when the application path is displayed
in the hardware status window. To verify that the application path is displayed:
1. Select Instances from the navigation panel.
2. Click the Status tab, in the Application Instances window, to view the application path
3. Verify that the application path is displayed. Verify that the target state is set to Run, the current state dis-
plays Ready, and the current HA state displays Active.
Figure 33. Application Status List