Sanyo DSR-3016 DVR User Manual


 
22
English
Recording Images
This digital video recorder can record images being monitored and alarm on the internal hard disk by the
methods specified below.
In order to record images, the necessary menu settings should be made beforehand in accordance with
the installation environment. (See p. 7)
Normal recording
This is a manual operation for recording live images that are currently
being viewed into the normal recording area.
1
Click the O button on the operating panel to start normal recording.
2
Click the P button on the operating panel to stop normal recording.
If more than one camera is connected to the digital video recorder for
monitoring, the images for all cameras that have been set in the REC
CAMERA GROUP specified by the NORMAL REC MODE SET setting will be
recorded, regardless of the number of live image display screens. (See p.
13)
Timer recording
This is for automatically recording an image that is being viewed into the
normal recording area at a specified time.
Timer recording is not possible during normal recording.
1
The conditions for timer recording (day of the week, time, recording
speed, etc.) are set beforehand using the TIMER SET menu screen.
(See p. 14)
2
Timer recording is started by clicking the Q button on the operating
panel and recording will start and stop automatically in accordance
with the specified times. The timer recording operation is indicated by
a TIMER STANDBY or TIMER RECORDING message appearing on
the screen.
3
To cancel timer recording, click the Q button on the operating panel
again when in timer recording standby mode.
If OLY AL-RC ON TMR has been selected as the ALARM RECORDING
setting (see p. 16), timer recording standby operation using the Q button
is not possible.
The display example is that for the
DSR-3016 model.
L8HBA_US(DSR-3016 NETWORK)(GB only).book 22 ページ 2003年3月28日 金曜日 午後6時44分