Axis Communications axis TV Cables User Manual


 
AXIS M1143–L
Events
Events
The Axis product can be congure d to perform actions w he n di ffe rent events occur, for exa m ple , start a recording whe n motion is
detected. The set of conditions that denes how and when the action is triggered is called an Action Rule.
Available Action Rule triggers and conditions include:
Applications — use installed applications to trigger the rule, see .
Detectors
- Day/Night Mode — trigger the rule when the product switches between day mode (IR cut lter on) and night
mode (IR cut lter off). This can for example be used to control an external infrared (IR) light connected
to an output port.
- Motion Detection — trigger the rule when motion is detected, see
Motion Detection on pa ge 24
.
- Tampering — trigger the rule when tampering is detected, see
Camera Tampering on page 24
.
Hardware
- Network trigger the rule if network connection is lost or restored. This can for example be used to start
recording to the SD card.
- Temperature — trigger the rule if the temperature falls outside or inside the operating range of the product. This
canforexamplebeusedtosendmaintenancenotications.
Input Signal
- Digital Input Port — trigger the rule when an I/O port receives a signal from a connected device, see
I/O
Ports on page 42
.
- Manual Trigger — trigger the rule using the Manual Trigger button in the Live View page, see
Controls on
theLiveViewPageonpage 8
. This can for example be used to validat
e actions during product installation
and conguration.
PTZ
- Moving — trigger the rule when the camera view moves due to a PTZ operation. This can for example be used
as an additi onal condition to prevent an action rule triggered by motion detection to record video while the
camera view moves due to a P TZ op
eration.
- Preset Reached —trigger
therulewhenthecamerastopsatapresetposition.Thiscanbeforexamplebeused
with the Send Images action to upload images from the p reset position.
Storage
- Available trigger the rule when the storage device is unmounted or removed. This can for example be
used to send maintenance notications.
- Full — trigger the rule when the storage device is full. Under normal opera tion, the oldest recordings will be
o
verwritten to prevent the storage device fr om becoming full.
- Locked — trigger the rule if the storage device is locked (write protected).
System
- System Initializing — trigger the rule when the p roduct is being started. This can for example be used to send a
notication when the product resta rts.
Time
27