2. Installation requirements
2.2 Electrical requirements
Power requirements
One ILite tile requires 200-240 VAC, 50-60 Hz, 1.45 amps at 230 VAC. Note that five ILite tiles correspond with a display surface of
1 m². Power split cables are used to link the power from ILite tile to ILite tile. However, MAXIMUM six (6) tiles may be connected in
parallel. So, one power source cable has to be provided per six (6) tiles. Every power source cable should be protected by a circuit
breaker or fuses rated 16 A / 250 VAC (15 A / 250 VAC in the USA and Canada).
Barco provides a range of power boxes, which meet the requirements of your ILite display. Contact Barco for
more information about power boxes and power requirements for your fixed ILite display.
Power system:
It is recommended to use a TN-S power distribution system (a power distribution system with a separate neutral and ground
ing
conductor) in order to avoid large ground current loops due to voltage differences in the neutral conductor. The total electrical
installation should be protected by an appropriately rated disconnect switch, circuit breakers and Ground Fault Current Interrupters.
The installation shall be done according to the local electrical installation codes. In Europ
e special attention should be given to EN
60364, the standard for electrical installation of buildings. In Germany VDE 0100 should be adhered to.
Disconnect device:
When the appliance inlets of the individual tiles are not accessible, the socket outlets supplying the rack shall be installed near the
equipment and be easily accessible, or a readily accessible general disconnect device shal
l be incorporated in the fixed wiring.
This equipment MUST be earthed:
In order to protectagainst risk of electric shock, the installation should be properly grounded. Defeating the purpose of the grounding
type plug will expose you to the risk of electric shock.
10
R5976522 FIXED ILITE DISPLAY 17/11/2006