7. Servicing
7.3 Replacement of the re-sync unit
Necessary tools
Slot screwdriver (100 x 4 mm).
How to replace the re-sync unit of an ILite tile ?
1. Release the two captive screws of the re-sync unit (M) using a slot screwdriver.
M
Image 7-2
2. Pull out the re-sync unit.
3. Place a new re-sync unit into position.
4. Fasten the two captive screws of the re-sync unit.
CAUTION: Be careful with the board to board connectors between the re-sync unit and the controller unit
underneath.
50 R5976522 FIXED ILITE DISPLAY 17/11/2006