Bosch Appliances MVM-BVRM DVR User Manual


 
The following sections describe the settings for VRM storage management. A distinction is
made between devices with firmware version 4.0 or later and devices with firmware versions
up to 3.5x.
Configuring local storage (firmware version 4.0 or later)
Main window > Devices tab > Expand
Pool n > Expand Devices > > Recording
> Recording Management
Before you make any changes, you must stop any active recordings. Active recordings are
indicated by an icon:
If you hover the pointer over the icon, detailed information about the active recordings are
displayed.
4
To stop the recordings, click the Recording Scheduler tab and click Stop Recording.
To configure local storage:
1. In the Local Media tab, select the storage medium on which local recording should take
place. Depending on the device type, different media will be available.
2. Click Add to add the selected medium to the disk space in use.
3. Ensure that the Rec. 2 option is activated for a medium in the list.
Click to ckeck Overwrite older recordingsRecording 2.
Related Topics
Recording Management tab (only firmware version 4.0 or later), page 32
Configuring alarm tracks (firmware up to 3.5x)
Main window > Devices tab > Expand Devices > > Recording > Storage Medium
To configure alarm tracks:
1. Select an entry in the Partition window.
2. Click Edit....
The Partition Settings dialog box appears.
3. Select the required number under Number of alarm tracks. One alarm event can be
recorded in each alarm track. The number of alarms entered can be recorded and
archived.
4. Select the required profile for pre-alarm recording under Pre-alarm profile.
5. Select the required time for pre-alarm recording under Pre-alarm time.
6. Select the required profile for post-alarm recording under Post-alarm profile.
7. Select the required time for post-alarm recording under Post-alarm time.
8. Click OK.
The appropriate number of alarm tracks has now been reserved for the camera. You can now
activate alarm track recording on the Recording Profiles tab and make the appropriate
settings.
Configuring failover recording mode
Main window > Devices tab > Expand > Expand Pool n > Expand Devices >
> Recording > Recording Preferences
Prerequisite: In the Pool tab, in the Recording preferences mode list, select Failover. If
Automatic is selected, the settings are performed automatically and cannot be configured.
7.8.1
7.8.2
7.9
18 en | Configuring a VRM system Video Recording Manager