Ref In -
Sets the mode of the AES Reference In/Out connectors. The options are:
Loop Loops the input through to the output, with no
termination resistor (termination is then about
1kohm, so several units can be daisy chained).
Loop.t As above, but terminates the input. Use at the end
of a daisy chain.
Int The output (and input in parallel – beware!) is
internally driven, with the same signal as AES 1.
A-SL -
Turns Auto-slaving On or Off. When set to On, connecting an AES/EBU
reference or a word clock in causes the unit to slave and lights the Slave LED.
If both are present, the unit picks the highest priority one (AES/EBU) unless the
Master/Slave button is used to move down the priority list. When set to Off, the
unit does not react when a reference is connected.
Offst -
Trims the appropriate VCXO frequency in master mode, by up to ±9.9ppm in
0.1ppm steps. Use the
Up and Down buttons to change this setting, hold a
button down to accelerate the change. The trim is remembered.
Loc -
Panel Lock, normally Off. Set to On to prevent unauthorised changes
using buttons. The menu has to be accessed to turn the lock off again.
End -