dCS 904 User Manual Manual for Software Version 1.5x and 1.36
dCS Ltd June 2000
Manual part no: DOC135904 iss 2B2
Page 24
135904ma2b2.pdf file available from website
Contact
dCS
on + 44 1799 531 999 email to: more@dcsltd.co.uk
(inside the UK replace + 44 with 0) web site: www.dcsltd.co.uk
T
YPICAL
A
PPLICATIONS
Using a dCS 904 to output DSD
PUSH
Analogue
CH1(L) CH2(R) Sensitivity
CH1(L) CH2(R)
Digital I/O
Reference In Reference Out AES1 AES2 AES3 AES4 CH1 CH2
In Out
SDIF-2/DSD
75R
Clk
Remote
In
Out
MAINS FUSE 2A(T)ON OFF
PUSH PUSH
CH1
CH2
Analogue source
DSD
Out
Figure 4 – DSD output configuration
do this: Set DSD in the menu to On.
do this: Most likely (check your other equipment) you will need word clock. Make
sure BNC O is set to CL64.
do this: Select your filter.
P3D units only:
do this: Set DSD to P3D or DSD4 instead of On as required
Using a Master Clock to Sync a dCS 904
PUSH
Analogue
CH1(L) CH2(R) Sensitivity
CH1(L) CH2(R)
Digital I/O
Reference In Reference Out AES1 AES2 AES3 AES4 CH1 CH2
In Out
SDIF-2/DSD
75R
Clk
Remote
In
Out
MAINS FUSE 2A(T)ON OFF
PUSH PUSH
AES 1 AES 2 AES 3 AES 4
AES/EBU Outputs
Wordclock Outputs
1 2 3 4 5 6
7 8 9 10 11 12
External
Sync
Remote
In
Loop
Out
Mains Fuse (2AT)
On Off
Single, Dual or
Quad AES
dCS 904
dCS 992
CH1
CH2
Analogue source
Figure 5 – Syncing a dCS 904 to a Master Clock
do this: Make sure A-SL (Autoslave) is On and DSD is set to Off