Kathrein MSK 33 Satellite TV System User Manual


 
Technical Appendix
100
Command overview data byte
An appropriate data byte must only be transmitted, if the command byte requires
the data byte(s). You can take these from the command byte table. To find out
which data byte must be transmitted to the respective command byte, please refer
to the data sheets of the respective unit.
Orbit position Switch position H/V Switch position LNB Data byte Recall
V Lo F0 80
V Hi F1 81
H Lo F2 82
1
H Hi F3 83
V Lo F4 84
V Hi F5 85
H Lo F6 86
2
H Hi F7 87
V Lo F8 88
V Hi F9 89
H Lo FA 90
3
H Hi FB 91
V Lo FC 92
V Hi FD 93
H Lo FE 94
4
H Hi FF 95
DiSEqC commands for Kathrein matrices
These commands are stored under the recall addresses 80...95 at the factory.
Command for Kathrein matrix 9xx-series
POS. A (Satellite1)
Low-band High-band
Range
Vert. Hor. Vert. Hor.
DiSEqC-
command
F0 00 38 F0 F0 00 38 F2 F0 00 38 F1 F0 00 38 F3
POS. B (Satellite 2)
Low-band High-band
Range
Vert. Hor. Vert. Hor.
DiSEqC-
command
F0 00 38 F4 F0 00 38 F6 F0 00 38 F5 F0 00 38 F7
Command for Kathrein matrix EXR 20
EXR 20 Range
POS. A POS. B
DiSEqC-
command
E0 00 22 E0 00 26
Command for Kathrein matrix EXR 22
EXR 22 Range
High-band Low-band
DiSEqC-
command
E0 00 24 E0 00 20