Measurement Possibilities
24
Measurement Possibilities
Level measurement
The MSK 33 is designed for the level measurements on receiving systems in the
measuring range of 30 dBµV to 130 dBµV. The level measurement is automati-
cally carried out after connecting the unit and setting a frequency and is displayed
on the display screen. The table shown below represents a brief overview of the
measurement possibilities of the MSK 33.
Measurement possibility
Type of
operation
Menus
DiSEqC 2.0 SAT SAT, LNB-CONTROL, DiSEqC
DiSEqC 2.0 TV TV, TV-CONTROL, DiSEqC
DiSEqC 2.0 FM RADIO, RADIO-CONTROL
UFOµ SAT SAT, LNB-CONTROL, DiSEqC
LNB current draw SAT SAT, LNB-CONTROL
Level measurement SAT analogue SAT Sat MENU - analogue
Level measurement TV analogue TV TV MENU - analogue
Level measurement RADIO ana-
logue
FM RADIO-MENU
Level measurement SAT digital SAT SAT, digital DVB-S
Level measurement TV digital TV TV, digital DVB-C or DVB-T
Min./Max. level measurement SAT SAT, SAT MEASURE
Min./Max. level measurement TV TV, TV MEASURE
Min./Max. level measurement FM RADIO
Current draw of a remotely fed-in unit TV TV, TV-CONTROL
Current drain of a remotely fed-in
unit
FM RADIO, RADIO-CONTROL
Sound carrier measurement
Nicam bit error measurement
Min./Max. level measurement
TV TV, analogue, TV MEASURE
IF level IF IF
Maximal input level
The maximal measurable input level of a carrier, which can be measured with the
MSK 33, is 130 dBµV. If a system with several carriers or programmes is meas-
ured, the maximal total capacity of all carriers determines the admissible input
level. The fed-in total capacity on the RF socket of the MSK 33 may not exceed
0.5 W.
The following table serves to approximately determine the maximal total capacity.
It only applies, if all the carriers contain the same level. When the carriers are dou-
bled, the maximal input level of the MSK 33 is reduced by 3 dB, refer to the table
below.
Number of the fed-
in carriers
Reduction
Maximal input level, if all carriers con-
tain the same level
4 TV programmes 129 dBµV
9 TV programmes -3 dB 126 dBµV
18 TV programmes -6 dB 123 dBµV
36 TV programmes -9 dB 120 dBµV
Exceeding the maximal input level may damage the input stages or the unit!
Intermodulation and overcontrol effects can occur for each maximal admis-
sible assignment!