Sat Operation
34
Rec adr r-zf t0 t1 t2 st
>02<244 1200 20 12 4 2
FRAME ADD COM DATA
TX E2 00 F2 1390--
Receiver field
In the receiver field, the setting status of the receiver 01...12
simulated by the MSK 33 is displayed.
Refer to the example to the left:
The receiver 2 is registered in the head station with the address 244. The remote
IF is 1200 MHz.
The collision pages are t0 = 20 ms, t1 = 12 ms and t2 = 4 ms. The status of the re-
ceiver 2 is „registered.“
TX field
In the TX-field, the currently selected telegram of the
respective receiver, 01...12, is displayed with the individual
DiSEqC bytes and represented in combination with the
individual DiSEqC commands.
The example shows: FRAME is E0 according to the programme commando
(PrgCom). Address ADD is 00 (is reserved). Polarisation byte COM F2 complies
with the selected polarisation and Sat planes. DATA complies with the set Sat IF in
MHz.
Operating the menus
Exit the DiSEqC menu.
In the set UFOµ DiSEqC mode, the available remote IF frequency is adopted. In
this case, the MSK 33 remains in the the UFOµ DiSEqC mode after exiting this
menu and is still connected with the head end allowing standard measurements to
be carried out. By repeatedly pressing this softkey (ring counter), select the UFOµ
DiSEqC menu.
By quickly pressing this softkey, the monitoring function is switched on, in which
the transmitted DiSEqC commands are recorded for a time period of up to 20 sec-
onds. A maximum of 5 events (RX0…RX4) with respectively up to 6 bytes
(Frame, Add, Com, Dat1, Dat2, Dat3) can be recorded between the head end and
the available satellite receivers. During the recording, the command are displayed
in the second line of the RX field by flashing.
The recording is automatically completed or prematurely cancelled by pressing
down the softkey for a longer time.
With the buttons, ▲ and ▼, the individual telegrams, RX 0…RX4, in the second
line can be called up.
With the aid of this softkey, the selected telegram in the lower TX field is transmit-
ted. If a message from the head station follows, the reply message is displayed in
the RX field. The reply message is accordingly taken over in the receiver field, e.g.
the remote IF.
By repeatedly pressing this softkey (ring counter), the DiSEqC telegram Virgin-Call-
For-Address, Call-For-Address, Program-Command or Switch-Off is selected.
The respective telegram code is displayed in the TX field.
With this softkey, the cursor buttons, ▲▼ and ◄►, are switched on.
Independent from the selected telegram, different editing fields can be selected
with the button, ◄ or ►. The selected fields are framed with arrows.
In the case of a programme command, the respective DiSEqC command, COM or
DATA, can be edited. Select the editing field using the cursor button, ▼or ▲.
In the COM field, the polarisation byte, F0...FF, (horizontal/vertical/high/low) are se-
lected with the aid of the cursor button, ▲ or ▼, and displayed in the softkey.
In DATA field, the Sat IF can directly changed in MHz via a numerical entry.
BACK
rx
Modus
tx+rx
Command
>
Command
>
Command
>
Command
>