Kathrein MSK 33 Satellite TV System User Manual


 
Copy Menu
62
Printing the measurement results
By pressing the softkey, the current measurement result along with the date and
time are printed out.
Printing out a measurement result in TV mode with:
- Date and time
- Channel number, frequency
- Analogue measurement (A), level.
If the function, „measure,“ is called up in the TV, Sat or FM menu, all the meas-
urements are printed out.
Printing out all measurements in TV mode
The printout contains the following measurement results:
- Date and time
- Audio carrier spacing TT1: - 13 dB
- Audio carrier spacing TT2: not available
- Audio carrier spacing NICAM: - 20 dB
- Bit error rate NICAM: 8.20E -06
- Minimal level: 52.5 dBµV
- Maximal level: 59 dBµV
- Channel: 10
- Video carrier frequency: 210.25 MHz
- Analogue measurement: A
- Current level: 56 dBµV
Printing out all measurements in Sat mode
The printout contains the following measurement results:
- Minimal level: 67.5 dBµV
- Maximal level: 69 dBµV
- Transponder frequency: 11373,15 MHz
- Analogue measurement: A
- Current level: 68 dBµV
Line feed