NEC 42PD3 Flat Panel Television User Manual


 
54
PLASMA MONITOR
05. Input Switch Change
Function
The external control equipment switches the
input of the display.
Transmission Data
CFH UA1 UA2 50H 01H DATA CKS
DATA : Input Select
01H : Video
07H : RGB1
08H : RGB2
0CH : RGB3
05H : HD/DVD
0FH : SCART
ACK
There is no ACK for which input was selected.
2FH UA1 UA2 50H 00H CKS
06. COLOR TEMP Select
Function
The external control equipment changes the
COLOR TEMP of the display.
Transmission Data
CFH UA1 UA2 00H 01H DATA00 CKS
DATA00
00H : HIGH
01H : LOW
02H : USER1
03H : USER2
04H : USER3
05H : USER4
ACK
6FH UA1 UA2 00H 01H DATA00 CKS
DATA00 :
00H : HIGH
01H : LOW
02H : USER1
03H : USER2
04H : USER3
05H : USER4
NOTE: When HIGH or LOW is selected with
COLOR TEMP, changes of the R/G/B GAIN data
will not be received.
07. RED Gain Data
Function
The external control equipment changes the
RED gain data of the display. (This command
will be received only when COLOR TEMP is
set for USER 1-4.)
Transmission Data
CFH UA1 UA2 10H 04H DATA00DATA03 CKS
DATA00 : USER PICTURE Gain Flag
01H
DATA01 : RED Gain Flag
01H
DATA02 : RED Gain
E0H : -32
|
FFH : -1
00H : 0
|
20H : +32
DATA03 : RED Bias
E0H : -32
|
FFH : -1
00H : 0
|
20H : +32
ACK
6FH UA1 UA2 10H 02H DATA00 DATA01 CKS
DATA00 : USER PICTURE Gain Flag
01H
DATA01 : RED Gain Flag
01H
08. GREEN Gain Data
Function
The external control equipment changes the
GREEN gain data of the display. (This com-
mand will be received only when COLOR
TEMP is set for USER 1-4.)
Transmission Data
CFH UA1 UA2 11H 04H DATA00DATA03 CKS
DATA00 : USER PICTURE Gain Flag
01H
DATA01 : GREEN Gain Flag
02H
DATA02 : GREEN Gain
E0H : -32
|
FFH : -1
00H : 0
|
20H : +32
DATA03 : GREEN Bias
E0H : -32
|
FFH : -1
00H : 0
|
20H : +32
ACK
6FH UA1 UA2 11H 02H DATA00 DATA01 CKS
DATA00 : USER PICTURE Gain Flag
01H
DATA01 : GREEN Gain Flag
02H
09. BLUE Gain Data
Function
The external control equipment changes the
BLUE gain data of the display. (This command
will be received only when COLOR TEMP is
set for USER 1-4.)
Transmission Data
CFH UA1 UA2 12H 04H DATA00DATA03 CKS
DATA00 : USER PICTURE Gain Flag
01H
DATA01 : BLUE Gain Flag
03H
DATA02 : BLUE Gain
E0H : -32
|
FFH : -1
00H : 0
|
20H : +32
DATA03 : BLUE Bias
E0H : -32
|
FFH : -1
00H : 0
|
20H : +32
ACK
6FH UA1 UA2 12H 02H DATA00 DATA01 CKS
DATA00 : USER PICTURE Gain Flag
01H
DATA01 : BLUE Gain Flag
03H
10. GAMMA Gain Data
Function
The external control equipment changes the
GAMMA gain data of the display.
Transmission Data
CFH UA1 UA2 13H 03H DATA00DATA02 CKS
DATA00 : USER PICTURE Gain Flag
01H
DATA01 : Gamma Gain Flag
09H
DATA02 : D-Gamma
00H : OFF
01H : ON
ACK
6FH UA1 UA2 13H 02H DATA00 DATA01 CKS
DATA00 : USER PICTURE Gain Flag
01H
DATA01 : Gamma Gain Flag
09H
Appendix