60
ⅥⅥⅥ
†
PLASMA MONITOR
36. SETTING MODE Select
Function
The external control equipment changes the
settings of the various items of the display.
Transmission Data
CFH UA1 UA2 04H 02H DATA00 DATA01 CKS
DATA00
Bit0
0: POWER ON MODE OFF
(LAST MEMORY)
1: POWER ON MODE ON
Bit2 Bit1
(Available only when Bit0 is set to 1)
0 0 : POWER ON MODE VIDEO
0 1 : POWER ON MODE RGB1
1 0 : POWER ON MODE RGB2,
DVD/HD, SCART
1 1 : POWER ON MODE RGB3
Bit3
0: POWER MANAGER OFF
1: POWER MANAGER ON
Bit4
0: LUM. LIMIT OFF
1: LUM. LIMIT ON
Bit5
0: ORBITTING OFF
1: ORBITTING ON
Bit7 Bit6
0 0 : GRAY LEVEL 1
0 1 : GRAY LEVEL 2
1 0 : GRAY LEVEL 3
DATA01
Bit0 Bit1
0 0 : RGB MODE STILL
1 0 : RGB MODE MOTION
0 1 : RGB MODE DTV
Bit2 Bit3
0 0 : INV/WT OFF
1 0 : INV/WT INV
0 1 : INV/WT ALL WHITE
1 1 : not used
Bit4 Bit5 RGB3 ADJ
0 0 : 1
1 0 : 2
0 1 : 3
Bit6
0: PROG. ORBIT OFF
1: PROG. ORBIT ON
Bit7 : 0 (fixed)
DATA02
Bit 0-7: H-DOT setting
01H: 1dot
|
14H: 20dot
Ignore values other than the above.
DATA03
Bit 0-7: V-LINE setting
01H: 1 line
|
14H: 20 line
Ignore values other than the above.
DATA04
Bit 0-7: TIME setting
01H : 1 min
|
05H : 5 min
Ignore values other than the above.
ACK
7FH UA1 UA2 04H 05H DATA00–04 CKS
NOTE: The INV function for DATA 01 will not have
last memory. It should be returned to default at
time of powering ON/OFF and selecting input.
NOTE: When tha plasma monitor is turned ON or
OFF, LONG LIFE MODE 3 setting is set to off and
the last data is not stored in memory.
ACK
7FH UA1 UA2 04H 02H DATA00 DATA01 CKS
37. SCREEN MODE Select
Function
The external control equipment switches the
screen mode of the display.
Transmission Data
CFH UA1 UA2 51H 01H DATA00 CKS
DATA00
02H : STADIUM
03H : ZOOM
04H : NORMAL
05H : FULL
ACK
6FH UA1 UA2 51H 01H DATA00 CKS
DATA00
02H : STADIUM
03H : ZOOM
04H : NORMAL
05H : FULL
38. PICTURE Mute On
Function
The external control equipment switches on
PICTURE Mute of the display.
Transmission Data
8FH UA1 UA2 3CH 00H CKS
ACK
2FH UA1 UA2 3CH 00H CKS
39. PICTURE Mute Off
Function
The external control equipment switches off
PICTURE Mute of the display.
Transmission Data
8FH UA1 UA2 3DH 00H CKS
ACK
2FH UA1 UA2 3DH 00H CKS
Appendix
40. MULTI MODE Select
Function
The master monitor changes MULTI MODE of
the slave.
Transmission Data
CFH UA1 UA2 03H 02H DATA00 DATA01 CKS
DATA00 : SCREEN DIVIDER SETTING
01H : Single mode
02H : -
03H : Multi mode 4 screens
04H : Multi mode 9 screens
DATA01 : POSITION OF DIVIDE
01H : Upper left selected (4 screens)
02H : Upper right selected (4 screens)
03H : Lower right selected (4 screens)
04H : Lower left selected (4 screens)
05H : -
06H : -
07H : Top left selected (9 screens)
08H : Top middle selected (9 screens)
09H : Top right selected (9 screens)
0AH : Middle left selected (9 screens)
0BH : Middle center selected (9 screens)
0CH : Middle right selected (9 screens)
0DH : Bottom left selected (9 screens)
0EH : Bottom middle selected (9 screens)
0FH : Bottom right selected (9 screens)
ACK
7FH UA1 UA2 03H 02H DATA00 DATA01 CKS
DATA00 (SCREEN DIVIDER SETTING)
01H: Single mode
02H: Multi-mode 2-screen
03H: Multi-mode 4-screen
04H: Multi-mode 9-screen
DATA01 (POSITION OF DIVIDE)
01H: Upper left screen selected (4 dividing)
02H: Upper right screen selected (4 dividing)
03H: Lower right screen selected (4 dividing)
04H: Lower left screen selected (4 dividing)
05H: Top screen selected (2 dividing)
06H: Bottom screen selected (2 dividing)
07H: Top left screen selected (9 dividing)
08H: Top middle screen selected (9 dividing)
09H: Top right screen selected (9 dividing)
0AH: Middle left screen selected (9 dividing)
0BH: Center screen selected (9 dividing)
0CH: Middle right screen selected (9 dividing)
0DH: Bottom left screen selected (9 dividing)
0EH: Bottom middle screen selected (9 dividing)
0FH: Bottom right screen selected (9 dividing)
NOTE: When the Multi-mode 2-screen is selected,
it returns an ACK as non-support.