NEC 42PD3 Flat Panel Television User Manual


 
56
PLASMA MONITOR
23. H-WIDTH Gain Data
Function
The external control equipment changes the H-
WIDTH (vertical expansion ratio) of the display.
(This command will be received only when multi
screen is ON.)
Transmissin Data
CFH UA1 UA2 20H 03H DATA00DATA02 CKS
DATA00 : USER POSITION Gain Flag
09
DATA01 : H-WIDTH Gain Flag
04H
DATA02 : H-WIDTH Gain
80H : -128
|
FFH : -1
OH : 0
|
7FH : +127
ACK
6FH UA1 UA2 20H 02H DATA00 DATA01 CKS
DATA00 : USER POSITION Gain Flag
09
DATA01 : H-WIDTH Gain Flag
04H
24. TIMER SWITCH
Function
The external control equipment changes the
timer on/off switching of the display.
Transmissin Data
CFH UA1 UA2 02H 01H DATA00 CKS
DATA00 :
0 : RESERVE OFF
1 : RESERVE ON
ACK
6FH UA1 UA2 02H 01H DATA00 CKS
DATA00 :
0 : RESERVE OFF
1 : RESERVE ON
17. H.POSITION Gain Data
Function
The external control equipment changes the H.
POSITION gain data of the display.
Transmission Data
CFH UA1 UA2 1AH 03H DATA00DATA02 CKS
DATA00 : USER POSITION Gain Flag
03H
DATA01 : H.POSITION Gain Flag
02H
DATA02 : H.POSITION Gain
C0H : -64
|
FFH : -1
00H : 0
|
40H : +64
ACK
6FH UA1 UA2 1AH 02H DATA00 DATA01 CKS
DATA00 : USER POSITION Gain Flag
03H
DATA01 : H.POSITION Gain Flag
02H
18. PHASE Gain Data
Function
The external control equipment changes the
clock phase of the display. (This command will
be received only when AUTO PICTURE is
OFF.)
Transmission Data
CFH UA1 UA2 1BH 03H DATA00 DATA01
DATA02 CKS
DATA00 : USER POSITION Gain Flag
03H
DATA01: PHASE Gain Flag
03H
DATA02: PHASE Gain
00H:0
|
1FH:31
ACK
6FH UA1 UA2 1BH 02H DATA00 DATA01 CKS
DATA00 : USER POSITION Gain Flag
03H
DATA01 : PHASE Gain Flag
03H
19. CLOCK Gain Data
Function
The external control equipment changes the
division ratio of the display. (This command will
be received only when AUTO PICTURE is
OFF.)
Transmission Data
CFH UA1 UA2 1CH 03H DATA00DATA02 CKS
DATA00 : USER POSITION Gain Flag
03H
DATA01 : CLOCK Gain Flag
04H
DATA02 : CLOCK Gain
E0H : -32
|
FFH : -1
00H : 0
|
20H : +32
ACK
6FH UA1 UA2 1CH 02H DATA00 DATA01 CKS
DATA00 : USER POSITION Gain Flag
03H
DATA01 : CLOCK Gain Flag
04H
22. V-HEIGHT Gain Data
Function
The external control equipment changes the V-
HEIGHT (horizontal expansion ratio) of the dis-
play. (This command will be received only when
multi screen is ON.)
Transmissin Data
CFH UA1 UA2 1FH 03H DATA00DATA02 CKS
DATA00: USER POSITION Gain Flag
09
DATA01: V-HEIGHT Gain Flag
03H
DATA02: V-HEIGHT Gain
80H : -128
|
FFH : -1
0H : 0
|
7FH : +127
ACK
6FH UA1 UA2 1FH 02H DATA00 DATA01 CKS
DATA00 : USER POSITION Gain Flag
09
DATA01 : V-HEIGHT Gain Flag
03H
Appendix