Paradise RCP2-1000 Universal Remote User Manual


 
RCP2-1000 RM Remote Controller Operations Manual 203987 Rev A 11
2.0 Introduction
This section provides information for the initial inspection, installation and external
connections for the RCP2-1000 RM redundant system controller.
2.1 Inspection
When the unit is received, an initial inspection should be completed. First, ensure that
the shipping container is not damaged. If it is, have a representative from the shipping
company present when the container is opened. Perform a visual inspection of the
equipment to make sure that all items on the packing list are enclosed. If any damage
has occurred or if items are missing, contact:
Paradise Datacom LLC
328 Innovation Blvd.
State College, PA 16803
Phone: +1 (814) 238-3450
Fax: +1 (814) 238-3829
2.2 Mounting
The RCP2-1000 RM Redundant Control Panel is designed to be mounted in a
standard EIA 9 inch equipment rack. The depth of the unit, excluding rear panel
connectors, is 13.3 inches (338 mm). The height is 1.75 inches (89 mm) or 1 rack unit.
2.3 Storage and Shipment
To protect the RCP2-1000 during storage or shipping, use high quality commercial
packing methods. Reliable commercial packing and shipping companies have facilities
and materials to adequately repack the equipment.
2.4 Prime Power Connection
An AC power connector (J1) is provided on the rear panel and provides universal AC
input by using auto-sensing power supplies. The AC input can operate over a range of
85-265 VAC, at 47-63 Hz. An On/Off switch is located adjacent to the AC input connec-
tor.