Paradise RCP2-1000 Universal Remote User Manual


 
RCP2-1000
Remote Control Panel
for Rack Mount SSPAs
203211 Rev C ECO 3171
4 OF 4
J7, Parallel I/O Connector Pin-out
Pin # Function / Description
1 Closed on Power Supply Fault Form C relay NC
2 Opened on Power Supply Fault Form C relay NO
20 Power Supply Fault Common
21
1. Standalone mode. Closed on Auxiliary Fault
2. 1:1 Redundancy Mode. Closed on Automatic switchover mode. Form C relay NC
22
1. Standalone Mode. Opened on Auxiliary Fault
2. 1:1 Redundancy Mode. Closed on Manual switchover mode. Form C relay NO
3 Auxiliary Fault\Auto-Manual Common
4 Closed on Mute. Form C Relay NC
5 Opened on Mute. Form C Relay NO
23 Mute Status Common
24 Closed on BUC Fault. Form C Relay NC
25 Opened on BUC Fault. Form C Relay NO
6 BUC Fault Common
7 Closed on High Temperature Fault. Form C Relay NC
8 Opened on High Temperature Fault. Form C Relay NO
26 High Temperature Fault Common
27
1. Standalone mode. Closed on Regulator Low Voltage Fault
2. 1:1 Redundancy Mode. Closed on HPA Standby. Form C relay NC
28
1. Standalone Mode. Opened on Regulator Low Voltage Fault.
2. 1:1 Redundancy Mode. Closed on HPA Online Mode. Form C relay NO
9 Regulator Low Voltage Fault\Standby-Online Common
10 Closed on DC Current Low Fault. Form C Relay NC
11 Opened on DC Current Low Fault. Form C Relay NO
29 DC Current Low Fault Common
30 Closed on Low Forward RF Fault. Form C Relay NC
31 Opened on Low Forward RF Form C Relay NO
12 Low Forward RF Fault Common
17 Mute/Unmute toggle input. 50mS Closure to ground to activate
35 HPA Standby input. 50mS Closure to ground to activate
36 Local/Remote toggle. 50mS Closure to ground to activate
37 Fault clear. 50mS Closure to ground to activate
19 Ground
34, 33, 32, 18,
16, 15, 14, 13
+5V Pull Up. 5mA Maximum output current