RCP2-1000 RM Remote Controller Operations Manual 203987 Rev A 9
1.3.2 Electrical Discharge Hazards
A spark can not only create ESD reliability problems, it can also cause serious safety
hazards. The following precautions should be taken when there is a risk of electrical
discharge:
• Follow all ESD guidelines.
• Remove all flammable material and solvents from the area.
• All probes and tools that contact the equipment should be properly insulated
to prevent electrical discharge.
• The work area should be secure and clear from non-essential items.
• Operators should never work alone on high voltage devices. There should
always be another person present in the same work area to assist in the
event of an emergency.
• Operators should be familiar with procedures to employ in the event of an
emergency, i.e. remove all power, CPR, etc.
1.4 Specification Summary
Table 1-1 contains a summary of the specifications of the RCP2-1000 RM redundant
system controller.
Configurations RCP2-1000 RM; 1:1 Redundant System
Switch Time Fault Detection, 20-50 msec
Total switchover, 100 msec maximum
Switch Drive 26 VDC @ 4 amps
Alarm Input Closure to Ground, (Ground = OK / Open = Fault)
Parallel I/O
Status Outputs
Control Inputs
Form C Relay Contacts (10 sets)
Contact Closure to Ground
Table 1-1: RCP2-1000 RM Specification Summary
AC Input Power 85-265 VAC, 47-63 Hz, 1 A max, > 0.93 power factor
Mechanical Dimensions 1.75 in. H x 19 in. W x 13.3 in. D [1 RU]
(89 mm H x 483 mm W x 338 mm D)
Weight 5 lb (2.3 kg)
Environmental Temperature 0 - 50
o
C