Paradise RCP2-1000 Universal Remote User Manual


 
20 203987 Rev A RCP2-1000 RM Remote Controller Operations Manual
3.2.1 Sys Info
The informative sublevel of the menu structure contains 8 pages, shown in Figure 3-3.
The "Up" and "Down" keys allow the user to navigate through the pages. Pressing the
"Left" and "Right" buttons will display the attenuation adjustment screen. Press "Enter"
to return to the first informative page.
The user can also browse between these pages by pressing the enter button on the
keypad (Note this function will not work if "Fault Latch" option is selected. Pressing the
"Enter" button will clear all system faults under this mode).
3.2.1.1 Sys Info Page 1
This is the HPA main status information page. The page shows:
HPA attenuation measured in dB ( Atten. (dB): XX.X) with accuracy of 0.1dB;
Forward RF Power in dBm with resolution of 0.1dBm;
Alarms presence, "FAULT!" or "None" will be displayed depending on the state of
HPA;
Reflected RF Power (if available) dB with resolution of 0.1dBm;
Figure 3-3: RCP2-1000 SysInfo Page Structure
Sys.Info
Atten.(dB):XX.X FrwrdRF(dBm):XX.X
Alarms:XXXXXX Ref.RF(dBm):XX.X
PS:XXXXXX LowRF:XXXXXX Fan:XXXXXX
AUX:XXXXXX VSWR:XXXXXX BUC:XXXXXX
RFSW1:XXXXXX State:XXXXXX
RFSW2:XXXXXX Mute:XXXXXX
Prtcl:XXXXXX Intrfc:XXXXX Buzzer:XXX
Baud:XXXXX Addrs.:XXX Latch:XXX
SysMode:XXXXXXX Stby:XXXX Unit:XXXX
Switch:XXXXX Ctrl:XXXXXX
Main
Menu
General System Info Menus
PS1(V):XX.X Boost1(V):XX.X DC(A):XX.X
PS2(V):XX.X Boost2(V):XX.X
Reg.Low:XXXXXX OverTemp:XXXXXX
Cur.Low:XXXXXX Temp.(C):XXX
Module1:XXXXXX Module3:XXXXXX
Module2:XXXXXX Module4:XXXXXX