Paradise RCP2-1000 Universal Remote User Manual


 
28 203987 Rev A RCP2-1000 RM Remote Controller Operations Manual
4.1.3 Voltage Regulator Output Low Fault
Fault effective when remote SSPA internal voltage regulators drop output voltage
below 8 volts. Fault always retains its last state when SSPA is muted. Fault threshold
value is factory fixed and can't be changed by the user. Fault state signaling: Front
Panel LED; Front Panel LCD; Serial Protocol Field, Form C contact closure (in Stand-
alone mode only).
4.1.4 High Temperature Fault
Fault is set when the remote SSPA's base plate reaches dangerously high tempera-
tures. Fault state signaling: Front Panel LED; Front Panel LCD; Serial Protocol Field,
Form C contact closure.
4.1.5 Low DC Current Fault
Major Fault. Fault is set when the remote SSPA indicates abnormally low current
consumption. Fault always retains its last state when the SSPA is muted. Fault thresh-
old value is factory fixed and can't be changed by the user. Fault state signaling: Front
Panel LED; Front Panel LCD; Serial Protocol Field, Form C contact closure.
4.1.6 Low Forward RF Fault
Fault is local to the RCP2-1000 RM unit. Fault alerts the user when the output power
falls below the threshold value. Threshold value is adjustable by the user with 1dBm
steps. Fault handling is adjustable by user. Selection for fault handling: Alert Only
(Minor Fault), Fault (Major Fault), Ignore (No Fault tracking) are available for user
through front panel menu and remote control protocol. Fault state signaling: Front
Panel LCD; Serial Protocol Field, Form C contact closure.
4.1.7 BUC Fault
Fault available only for Rack Mount SSPAs with the internal BUC option. In general a
BUC fault is a major fault. Fault state signaling: Front Panel LCD; Serial Protocol Field,
Form C relay contact closure.
4.1.8 Auxiliary Fault
User configurable fault. Fault condition occurs when HPA senses change of the state
on external auxiliary fault input line. Fault effect depends from the costumer settings for
this fault. Fault state signaling: Front Panel LCD; Serial Protocol Field, Form C contact
closure (in Standalone mode only).