Plasmon LF 6602 DVD Player User Manual


 
PLASMON LASER MAGNETIC STORAGE - LF 6602 USER MANUAL
Page 16
TEMPERATURE, HUMIDITY AND ALTITUDE
The following table lists the temperature, humidity and altitude limits for the LF 6600 drives installed in the
LF 6602.
Temperature, Humidity and Altitude Limits
1 Storage specifications are for 90 days maximum in Plasmon LMS packaging. No condensation is permitted. Transit spec-
ifications are based on a maximum 1-week period in a factory-sealed container.
2 Maximum operating temperature is 42 _C for a free-standing drive at sea level unless otherwise stated. Maximum oper-
ating temperature is derated linearly above 300 m altitude to 38 _C at 2,000 m altitude.
3 See the LD 6100/LF 6600/LF 6602 Product Specification (P/N 97653977) for more information concerning the tempera-
ture and humidity operating range.
4 Media limits maximum operating altitude to 2000 m. For conditions and limits pertaining to the media, refer to the LM
6000 Media Specification (P/N 97647044).
CONDITION OPERATING NONOPERATING
STORAGE/TRANSIT
1
Temperature
10° to 42° C
2
(50° to 108° F)
-40° to 66° C
(-40° to 151° F)
-40° to 66° C
(-40° to 151° F)
Maximum Rate of
Change
11° C/hr
(20° f/hr)
20° C/hr
(36° F/hr)
20° C/hr
(36° F/hr)
Humidity
(Noncondensing)
10 to 90% 5 to 95% 5 to 95%
Maximum Rate of
Change
10%/hr 10%/hr 10%/hr
Maximum Wet
Bulb
Temperature
28° C
(82° F)
46°C
(115° F)
46°C
(115° F)
Minimum Dew
Point
2° C
(35.6°)
2° C
(35.6°)
2° C
(35.6°)
Altitude -300 to 3,000 m
(-984 to 9840 ft)
without Media
-300 to 2,000 m
(-984 to 6562 ft)
with Media
-300 to 3,000 m
(-984 to 9840 ft)
Storage
-300 to 3,000 m
(-984 to 9840 ft)
Transit
-300 to 12,000 m
(-984 to 40,000 ft)
with Media