Plasmon LF 6602 DVD Player User Manual


 
97654438 E
Page 45
POWER-ON PROCEDURE
Perform the following procedure to power on each LF 6600:
1) Ensure that the LF 6600 is properly connected (refer to the SCSI Bus Consideration
section).
2) Refer to the Media Insertion and Removal section and insert a cartridge into slot 1. If slot 1
is empty, the LF 6600 will display "1 Empty" on the DOC shortly after initial power on.
NOTE
Slot 1 is the factory setting for the media autoload configuration
option.
If this option has been changed by the user, all references to slot 1 in
this manual apply instead to the slot number selected in the autoload
configuration option. Refer to the Configuration mode section for more
information on setting configuration options.
3) Set the AC Power Switch to the ON ( I ) position and verify that air is flowing through the
LF 6600.
4) Verify that the WRITE PROTECT indicator is illuminated briefly.
5) Verify that the "Selftest" message is displayed on the DOC.
The "Selftest" message indicates that the power-on selftests are running. When the power-on selftests are
completed without errors, the drive will perform a test to determine which slots in the shuttle are occupied
by media cartridges and then will load media #1.
When the "1 Ready" message is displayed, the LF 6600 has passed the power-on selftests and has
successfully loaded the LM 6000 media cartridge in slot 1.
6) Verify that the "Selftest" message displayed on the DOC is replaced by the "1 Ready"
message.
7) Refer to Modes of Operation section to familiarize yourself with the LF 6600 modes of
operation. View the current drive configuration parameters by following the procedure in
Viewing the Configuration section. The factory settings can be changed to custom
settings of your choice by following the instructions provided in the Configuration Mode
section.
The LF 6600 is now in the normal Operating mode, and is ready to be controlled and accessed by a host
system.